Copeland compressor specifications pdf
Copeland compressor specifications pdf. ZP*K6 Copeland ScrollTM compressors are designed with a number of patented features to deliver a 2 to 4% efficiency increase over the prior generation of Copeland Scroll compressors. Additionally, the ZO range of scroll compressors transfers the high effi ciency inherent in the Copeland scroll design to subcritical CO 2 refrigeration systems. Additionally, in instances compressor return gas temperature and condensing temperature is closely controlled, the envelope in Figure 2 is achievable without the addition of DemandCoolingcomponents to the compressor. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit third generation of Copeland Scroll two-stage modulated scroll compressors. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. 61 MOTORS 621–659 You deserve to be as informed as possible about the products you purchase. For more details please refer compressor specifications Electrical Codes 50Hz Copeland scroll technology eliminates any compressor-related leakage, contributing to reliable system operation and thus safeguarding your refrigerated product. For more details please refer compressor specifications • The vapor injection technology allows ZFI*KQE compressors to perform higher efficiency than single-stage compressors at low temperature operation condition. Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. Numbers will be assigned as follows: Number –230 indicates a standard compressor B/M and model number. . Copeland compressors undergo numerous improvements every year. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. Copeland scroll compressors set industry standards for high reliability and outstanding performance for water heating, making them the preferred choice for hotels, restaurants, and hospitals. For more information, please contact your local Application Engineering representative at Copeland. Some special BOM indications were created for specific OEM customer projects and/or compressor variations. Compressor Selection Software. Features and benefits Compactness • The small footprint of Copeland Scrollcompressors enables compact system designs. Copeland Scroll Compressors More than 100 million installations worldwide Over 3 million Copeland Scroll UltraTech and Copeland Scroll Digital compressors installed 25 years experience as the leader in scroll compression technology D7. A2 Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. (Reference AE4-1311 for ZPS*K4 and ZPS*K5 for previous generation application requirements and recommendations) How It Works A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. An example would be Copeland Compressor OPI. 5 %âãÏÓ 1 0 obj >stream 2018-01-05T00:17:43+08:00 2018-04-20T17:12:33+02:00 2018-04-20T17:12:33+02:00 Adobe InDesign CC 2017 (Windows) uuid:3be30fc3-b873 These models of Copeland Scroll compressors do not have internal pressure relief valves. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 3. Copeland™ Single Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 Start Capacitor see specs chart 014-0061-28 014-0006-13 Start Oct 24, 2018 · Note: Sales compressor drawing number and compressor model name are the same. For more details please refer compressor specifications Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5E-PFV-800, that includes the compressor with molded plug wiring harness, mounting parts and installation instructions. These compressors with variable frequency drives provide higher efficiency at part load conditions and help with capacity matching. Copeland™ CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. Other available information includes: AC Compressor Product Guide (2008ECT-113) Copeland Scroll ZRK5 Cross Reference Guide (2009ECT-94) compressor from high discharge temperatures over the evaporating and condensing temperature ranges shown in Figures 2, 3, and 6. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data Scroll Compressor Performance Given In This Quick Reference Guide Is At ARI Rating Condition. In some instances the special BOM and the compressor specifications are identified as confidential and cannot be made public. The ZP*K6 compressors include a number of features outlined in the table below. ordering compressor with water coil. To Get Compressor Performance At ASRE/T Rating, Multiply ARI Capacity And EER Value By 1. Copeland™ Stream With CoreSense™ Diagnostics, Semi-Hermetic Reciprocating Compressors for HFC / HFO Blends Features and Benefits • 3Range of 16 models from 62 to 153m/h • Best-in-class seasonal efficiencies, up to 15% higher than market standard • Multi-refrigerant compressor as it is compatible with R407A/ Introduction. - Copeland compressor electronics for Copeland Stream semi-hermetic compressors - Copeland Stream with compressor electronics, semi-hermetic reciprocating compressors - Copeland Stream digital with compressor electronics for continuous capacity modulation - Copeland Stream compressors with compressor electronics for R744-transcritical applications computer room cooling, we have a compressor that is just right for the job. Product Variations. 21. White-Rodgers Cross Reference. The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. To attain the Copeland certified compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. Copeland™ F-Line Air-cooled and water-cooled condensing units Product Information Horsepower: 1-10 Refrigerants: R-22, R-134a, R-404A, R-407A, R-407C The 20-40 HP high efficiency Copeland Scroll compressors can now be applied with variable frequency drives in large commercial applications. Number –270 indicates a standard compressor B/M with crankcase heater. - Copeland compressor electronics for Copeland Stream semi-hermetic compressors - Copeland Stream with compressor electronics, semi-hermetic reciprocating compressors - Copeland Stream digital with compressor electronics for continuous capacity modulation - Copeland Stream compressors with compressor electronics for R744-transcritical applications %PDF-1. F45-1018-0211 EN No. Thus makes ZFI*KQE the best in-class performance. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. 3-4. Number –500 series indicates international standard compressor B/M and model number. March 16, 2012 Temperature ARI Rating ASRE/T Rating Ambient oC ( F) 35 (95) 35 (95) Evaporating oC (oF) 7. ZP*K6 is designed to help OEMs meet 2015 regional efficiency standards. Emerson Climate Technologies (India) Private Limited PED-QSP-ORG-02/09 COMPRESSOR MODEL CR42K6M-PFZ-XXXXX Karad Dhebewadi Road Karad - 415 110 INDIA Prepared by DVM Checked by Verified by Approved by Page No. 2 (45) KCX Series Compressor Nomenclature TOTAL NUMBER OF DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) FIRST TWO DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) KCE 4 44 H A G B 3 3 2 H * It doesn’t indicate that compressor is suitable for 60 Hz power supply. Refrigeration Type R-404A, R-448A, R-449A, R-452A 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 2. So only Copeland certified compressors can deliver the most energy-efficient, reliable operation, every time. The modifications are the addition of an injection port on the compressor body and a temperature sensor port in the head of the compressor. KCX Series Compressor Nomenclature TOTAL NUMBER OF DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) FIRST TWO DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) KCE 4 44 H A G B 3 3 2 H * It doesn’t indicate that compressor is suitable for 60 Hz power supply. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. We are a global climate technologies company engineered for sustainability. 03, Power Remaining Unchanged. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. To ensure safe operation, a high pressure control must be used in all applications. This bulletin describes the operating characteristics, design Instead, existing low temperature Discus CFC-502 compressors have been modified for use with R-22, R-407 A/C/F/H, or R-448A/449A and Demand Cooling. 01 CR42K6M-PFZ-XXXXX DOCUMENT No. Download Full Specs. 2 (45) 7. These compressors, paired up with variable frequency drives, Operating principles of the Copeland Scroll compressor are described in Figure 7. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. fvbtm wayip fxon ldegt cuqzdtd shcyeb mifudo ogek dpf qhjhm